Overhead Ionizing Blowers
Static Control > Ionizers > Overhead Ionizing Blowers
The centurION offers superior balance performance with its novel emitter array design (US patent #6717792) and high-gain dual feedback circuitry. Using corona DC ion technology, the centurION eliminates charges cleanly, quickly and reliably in cleanroom workstation applications where electrostatic discharge (ESD) is a concern. It is designed for applications where even very low levels of static charge can damage sensitive components.
Specially selected components ensure cleanliness of the centurION’s output air to meet or exceed Class 10 particle limits. The centurION’s final assembly, final test, and packaging take place in a Class 100 cleanroom to minimize risk of contamination.
Features include:
- Rapid static charge neutralization
- +/-3 V offset voltage (balance)
- Class 10 cleanroom ISO-4 compatible
- Fan speed control
- Patented emitter design
Specifications:
Offset Voltage: ±3 V from set point, set point adjustable to 0 V.
Offset Balance: Adjustable to zero
Operating Temperature: 32°F (0°C) to 122°F (50°C)
Line Voltage: 100-240 VAC, 50/60 Hz
Discharge Time:
2 Fan Unit at 18" 1000-100 V < 3 seconds
3 Fan Unit at 18" 1000-100V < 3 seconds
Air Volume 2 Fan Unit:
Fan Speed Low 100 CFM (40 l/s)
Fan Speed High 260 CFM (80 l/s)
Air Volume 3 Fan Unit:
Fan Speed Low 150 CFM (60 l/s)
Fan Speed High 345 CFM (120 l/s)
Air Coverage:
2 Fan Unit 2
3 Fan Unit 2
Weight:
2 Fan Unit 8 lbs. (3.62 kg.)
3 Fan Unit 11 lbs. (5 kg.)
Part Numbers:
Cont. Euro.:
2 Fan Unit 4009431
3 Fan Unit 4009424
UK:
2 Fan Unit 4009432
3 Fan Unit 4009425
Not sure exactly what you’re looking for or just want clarification? We’d be happy to chat with you and clear things up for you. Anytime!